ID900-TCSPC

Time Taggers & Digital Delay Generators by ID Quantique (CH)

ID900-TCSPC – Time Taggers & Digital Delay Generators by ID Quantique

Overview

Time-correlated single-photon counting version of the ID900 Time Controller (ID900‑TCSPC) offering high‑resolution time‑tagging, counting and continuous histogramming on four input channels for picosecond‑resolved photon timing experiments.

Specifications

Timing Jitter40 (standard resolution mode, single‑channel RMS) 8 (high‑resolution mode with HR add‑on, single‑channel RMS) ps
Digital Resolution100 (standard bin width) 13 (high‑resolution mode with HR add‑on) ps

Request a quote

Sign in to QHUB and click “Request Quote” to send an RFQ for the ID900-TCSPC directly to ID Quantique. Manufacturer product page.

Similar Time Taggers & Digital Delay Generators

  • HydraHarp 500 — PicoQuant
    Timing Jitter: 2.5 (single‑channel rms timing jitter). 3.5 (between‑channel rms timing jitter). ps · Digital Resolution: 1 ps
  • ID1000-MASTER — ID Quantique
    Timing Jitter: 40 (standard resolution mode, single‑channel RMS) 8 (high‑resolution mode with HR add‑on, single‑channel RMS) ps · Digital Resolution: 100 (standard bin width) 13 (high‑resolution mode with HR add‑on ps
  • ID1000-TCSPC — ID Quantique
    Timing Jitter: 28 ps · Digital Resolution: 1 ps
  • ID900-DG — ID Quantique
    Timing Jitter: 40 (standard mode, single‑channel RMS) 8 (with high‑resolution option, single‑channel RMS) ps · Digital Resolution: 100 (standard bin width) 13 (with high‑resolution option) ps
  • ID900-MASTER — ID Quantique
    Timing Jitter: 40 (standard mode, single‑channel RMS) 8 (with high‑resolution option, single‑channel RMS) ps · Digital Resolution: 100 (standard bin width) 13 (with high‑resolution add‑on) ps
  • Logic16 — UQDevices
    Timing Jitter: 71.6 (RMS, configuration A, 156.25 ps bin). 58.5 (RMS, configuration B, 78.125 ps bin). ps · Digital Resolution: 156.25 (configuration A bin width). 78.125 (configuration B bin width). ps
  • MultiHarp 150 — PicoQuant
    Timing Jitter: 35 ps · Digital Resolution: 5 (time bin width / electrical resolution for MultiHarp 150 P variant) 80 (time bin width / electrical resolution for MultiHarp 150 N variant) ps
  • MultiHarp 160 — PicoQuant
    Timing Jitter: <45 (single‑channel rms jitter for 16+1 channel configuration). ps · Digital Resolution: 5 ps
  • QO-TDCC8 Time Tagger 8-Channel — Quark Optical
    Timing Jitter: 20 ps · Output Channels: 8 N/A
  • QTM — Qblox
  • quTAG – standard — Qutools
    Timing Jitter: 3.0 ps · Digital Resolution: 1 ps
  • quTAG HR – High Resolution — Qutools
    Timing Jitter: 2.4 ps · Digital Resolution: 1 ps

Compare all Time Taggers & Digital Delay Generators