Home › Marketplace › Photonics › SPAD Modules & Single-Photon Detectors
SPAD Modules & Single-Photon Detectors
Compare 58 SPAD Modules & Single-Photon Detectors from 17 vendors including AUREA, Axiom Optics, EIPEKS, Excelitas, Hamamatsu, ID Quantique and 11 more. Filter and compare by Wavelength Range, Minimum Peak PDE, Max Dark Count and Max Jitter. Request a quote directly from the manufacturer on QHUB.
C11202-050 — HamamatsuWavelength Range: 320–900 nm · Minimum Peak PDE: 70 % · Max Dark Count: 7 cps C11202-100 — HamamatsuWavelength Range: 320–900 nm · Minimum Peak PDE: 70 % · Max Dark Count: 30 cps · Photosensitive Area Um: 100 C13001-01 — HamamatsuWavelength Range: 370–900 nm · Minimum Peak PDE: 45 % · Max Dark Count: 7 cps C14076-01 — HamamatsuWavelength Range: 370–900 nm · Minimum Peak PDE: 45 % · Max Dark Count: 7 cps C16531-050GD — HamamatsuWavelength Range: 400–1000 nm · Minimum Peak PDE: 65 % · Max Dark Count: 20 cps C16531-100GD — HamamatsuWavelength Range: 400–1000 nm · Minimum Peak PDE: 65 % · Max Dark Count: 150 cps · Photosensitive Area Um: 100 C16533-050GD — HamamatsuWavelength Range: 400–1000 nm · Minimum Peak PDE: 45 % · Max Dark Count: 20 cps C16534-050GD — HamamatsuWavelength Range: 400–1000 nm · Minimum Peak PDE: 45 % · Max Dark Count: 20 cps COUNT — LASER COMPONENTSWavelength Range: 400–1000 nm · Minimum Peak PDE: 70 % · Max Dark Count: 10 cps COUNT NIR — LASER COMPONENTSWavelength Range: 400–1000 nm · Minimum Peak PDE: 50 % · Max Dark Count: 50 cps COUNT T — LASER COMPONENTSMax Jitter: 350 ps CPDS-1000 Correlated Photon Detection System — NuCryptGIGAXEA — AUREAMinimum Peak PDE: 30 % · Max Jitter: 200 ps HERMES — Micro Photon Devices (MPD)Wavelength Range: 300–1000 nm · Minimum Peak PDE: 42 % · Max Dark Count: 100 cps ID Qube NIR Gated — ID QuantiqueWavelength Range: 900–1700 nm ID Qube Series NIR Free-Running — ID QuantiqueMinimum Peak PDE: 35 % · Max Dark Count: 200 cps · Max Jitter: 200 ps ID Qube Series NIR Gated — ID QuantiqueMinimum Peak PDE: 35 % · Max Jitter: 200 ps ID Qube ULN — ID QuantiqueMinimum Peak PDE: 35 % · Max Dark Count: 200 cps · Max Jitter: 200 ps ID230 — ID QuantiqueWavelength Range: 900–1700 nm · Cooling Temperature: -50 to -90 °C · Detection Efficiency: Up to 25% at 1550 nm · Dimensions: 60 × 27 × 25 cm ID230 Infrared Single-Photon Detector — ID QuantiqueMinimum Peak PDE: 25 % · Max Dark Count: 50 cps · Max Jitter: 150 ps InGaAs Deep Cooled Free Running Single Photon Detector — LONTENWavelength Range: 900–1700 nm · Minimum Peak PDE: 20 % · Max Dark Count: 100 cps InGaAs Free Running Single Photon Detector — LONTENWavelength Range: 900–1700 nm · Minimum Peak PDE: 15 % · Max Dark Count: 500 cps · Max Jitter: 80 ps InGaAs Gated Single Photon Detector — LONTENWavelength Range: 900–1700 nm · Minimum Peak PDE: 25 % · Max Dark Count: 300 cps · Max Jitter: 200 ps InGaAs Geiger APD Array (64x64) — EIPEKSWavelength Range: 950–1650 nm · Minimum Peak PDE: 20 % · Max Dark Count: 5000 cps · Max Jitter: 500 ps InGaAs Single Photon Detector QDC-T4-00 — QubitriumWavelength Range: 1000–1650 nm · Minimum Peak PDE: 20 % · Max Dark Count: 5000 cps · Max Jitter: 1000 ps InGaAs Single-Photon Array (4x4) — EIPEKSWavelength Range: 950–1650 nm · Minimum Peak PDE: 10 % · Max Dark Count: 10000 cps · Max Jitter: 500 ps IRSPD1 — S-Fifteen InstrumentsTiming Jitter: <300 ps LYNXEA — AUREAWavelength Range: 900–1700 nm · Minimum Peak PDE: 30 % · Max Dark Count: 800 cps · Max Jitter: 150 ps Miniaturized Free Running Single Photon Detector QCD600C — LONTENWavelength Range: 900–1700 nm · Minimum Peak PDE: 13 % · Max Jitter: 500 ps PDM — Micro Photon Devices (MPD)Wavelength Range: 400–1000 nm · Minimum Peak PDE: 80 % · Max Dark Count: 1 cps PDM Series — PicoQuantWavelength Range: 400–1000 nm · Minimum Peak PDE: 49 % · Max Dark Count: 5 cps · Max Jitter: 50 ps PDM-IR — Micro Photon Devices (MPD)Wavelength Range: 900–1700 nm · Minimum Peak PDE: 25 % · Max Dark Count: 200 cps · Max Jitter: 100 ps PDM-UV — Micro Photon Devices (MPD)Wavelength Range: 300–1000 nm · Minimum Peak PDE: 43 % · Max Dark Count: 100 cps QCD 600B-H — EIPEKSWavelength Range: 900–1700 nm · Minimum Peak PDE: 35 % · Max Dark Count: 4000 cps · Max Jitter: 100 ps QCD 600B-S — EIPEKSWavelength Range: 900–1700 nm · Minimum Peak PDE: 25 % · Max Dark Count: 2000 cps · Max Jitter: 150 ps QCD 620 — EIPEKSWavelength Range: 900–1700 nm · Minimum Peak PDE: 20 % · Max Dark Count: 100 cps QCD-500A — EIPEKSWavelength Range: 900–1700 nm · Minimum Peak PDE: 25 % · Max Dark Count: 1500 cps · Max Jitter: 200 ps quPSI — QutoolsWavelength Range: 500–900 nm · Minimum Peak PDE: 30 % · Max Jitter: 500 ps quTD — QutoolsWavelength Range: 450–1050 nm · Minimum Peak PDE: 30 % · Max Dark Count: 1500 cps Si-Single Photon Detector QDC-V2-00 — QubitriumWavelength Range: 300–1000 nm · Minimum Peak PDE: 80 % · Max Dark Count: 1000 cps · Max Jitter: 1000 ps Single Photon Imaging System — QuantumcTekInput Voltage: 220 V · Laser Power: <50 mW · Laser Wavelength: 1064 nm · Power: 100 W SPAD Single-Photon InGaAs/InP Avalanche Photodiodes APD — WooriroWavelength Range: 1100–1600 nm · Minimum Peak PDE: 20 % · Max Dark Count: 2000 cps SPAD23 / pSPAD — Axiom OpticsMinimum Peak PDE: 50 % · Max Dark Count: 100 cps · Max Jitter: 20 ps SPAD512 & SPADα — Axiom OpticsMinimum Peak PDE: 50 % · Max Dark Count: 25 cps SPADλ — Axiom OpticsMinimum Peak PDE: 50 % · Max Jitter: 130 ps SPCM-AQ4C — ExcelitasWavelength Range: 400–1060 nm · Minimum Peak PDE: 60 % SPCM-AQRH — ExcelitasWavelength Range: 400–1064 nm · Minimum Peak PDE: 70 % SPCM-AQRH-TR — ExcelitasWavelength Range: 400–1060 nm · Minimum Peak PDE: 75 % · Max Jitter: 250 ps SPCM-NIR — ExcelitasMinimum Peak PDE: 70 % SPCM20A(/M) — THORLABSWavelength Range: 350–900 nm · Minimum Peak PDE: 35 % · Max Dark Count: 25 cps SPCM50A — THORLABSWavelength Range: 350–900 nm · Minimum Peak PDE: 35 % · Max Dark Count: 150 cps SPD_AC_NIR — AUREAWavelength Range: 900–1700 nm · Minimum Peak PDE: 30 % · Max Dark Count: 800 cps · Max Jitter: 150 ps SPD_OEM_NIR — AUREAWavelength Range: 900–1700 nm · Minimum Peak PDE: 30 % · Max Dark Count: 700 cps · Max Jitter: 150 ps SPDMA — THORLABSWavelength Range: 350–1100 nm · Minimum Peak PDE: 66 % · Max Dark Count: 75 cps SPDMH2 — THORLABSWavelength Range: 400–1000 nm · Minimum Peak PDE: 50 % · Max Dark Count: 50 cps SPDMH2F — THORLABSWavelength Range: 400–1000 nm · Minimum Peak PDE: 50 % · Max Dark Count: 100 cps SPDMH3 — THORLABSWavelength Range: 400–1000 nm · Minimum Peak PDE: 50 % · Max Dark Count: 250 cps SPDMH3F — THORLABSWavelength Range: 400–1000 nm · Minimum Peak PDE: 50 % · Max Dark Count: 250 cps
Vendors of SPAD Modules & Single-Photon Detectors
AUREA, Axiom Optics, EIPEKS, Excelitas, Hamamatsu, ID Quantique, LASER COMPONENTS, LONTEN, Micro Photon Devices (MPD), NuCrypt, PicoQuant, QuantumcTek, Qubitrium, Qutools, S-Fifteen Instruments, THORLABS, Wooriro